Home > Accessories > Calibration Gas- MGC-Q-58
We found 4 results matching your criteria.
Sort By:
Page of 1
Gas Clip Technologies MGC 4-Gas Monitor, Multi Gas Clip with Infrared Combustible Sensor (4 Gas/H2S, CO, O2 & LEL) Gas Clip Technologies MGC-P-PUMP Multi Gas Clip Pump Pellistor 4 Gas Detector, internal Pump for H2S, CO, O2 & LEL Gas Clip Technologies MGC-IR-PUMP Multi Gas Clip Pump IR 4 Gas Detector, Internal Pump & Infrared Combustible Sensor (H2S, CO, O2 & LEL)
Gas Clip Technologies MGC 4-Gas Monitor, Multi Gas Clip with Infrared Combustible Sensor
(4 Gas/H2S, CO, O2 & LEL)

Infrared Combustible Sensor

Longest Battery Life of Any Portable Gas Detector! Can Go a Full 2 Months Without a Charge!
Gas Clip Technologies MGC-P-PUMP Multi Gas Clip Pump Pellistor 4 Gas Detector, Internal Pump for H2S, CO, O2 & LEL



Features

  • 12 hour continuous run time - Operates with pump on for 52 hours continuously
  • Detects combustible gases (LEL), hydrogen sulfide (H2S), carbon monoxide (CO) & oxygen (O2)
  • 1 year calibration cycle saves valuable time & test gas
  • Will work in inert environments, no need for oxygen
  • Powerful but quiet pump draws from up to 75 feet
  • Stainless steel gas inlet
  • Detects accurately in oxygen-depleted environments
  • Low maintenance cost - infrared LEL sensor is immune to poisons
  • Simple to use, one button operation - large, easy to read screen
  • Lightweight & durable - alligator clip clamps on tight


Gas Clip MGC-IR-PUMP Specifications

  • Size • Weight 5.7” H x 3.0” W x 1.5” D (147 x 78 x 38.3 mm.) • 12.4 oz. (352g)
  • Temperature -4˚ to +122˚F (-20˚ to +50˚C)
  • Humidity 5% to 100% RH (non-condensing)
  • Battery Life Pellistor version.-.12 hours continuous
  • Charge Time 4 - 6 Hours
  • Alarms Visual, vibrating & audible (minimum 95 dB) Pump, Low, High, STEL, TWA & OL (Over Limit)
  • LED’s 4 Red alarm bar LEDs Yellow back-light (activated on button press) Red back-light (activated on alarm condition) Yellow maintenance notification LED
  • Display High viewing angle alphanumeric Liquid Crystal Display (LCD)
  • Logs 25 Bump tests, 25 events, & 25 calibrations Continuous 1 second data logging (typical capacity >2 months)
  • Tests Full function self-test upon activation Sensors, battery and circuitry tests run continuously
  • Ratings EMC Directive 2004/108/EC IP 67
  • Gas Inlet 1/8” Stainless steel barbed fitting
  • Pump Draw Sample from up to 75 ft. (23m.)




What's included:
  • Charger,
  • 10 foot sampling hose
  • Stainless steel diffusion stone
  • 10 additional filters (five hydrophobic and five particulate)
  • Calibration certificate
  • Quick Start Guide
.
Certifications & Approvals for MGC-IR-PUMP & MGC-P-PUMP

  • CSA: C22.2 No. 157 and C22.2 152 (MGC-IR-PUMP only)
  • Class I, Division 1, Group A, B, C, and D
  • MGC-IR-PUMP: Class I, Zone 0, AEx ia IIC T4 Ga
  • MGC-P-PUMP: Class I, Zone 1, AEx d ia IIC T4 Gb
  • UL-913 and ANSI/ISA-S12.13.01
  • IECEx: IECEx CSA 14.0029
  • IEC 60079-0:2011, 60079-1:2007, 60079-11:2011
  • MGC-IR-PUMP: Ex ia IIC T4 Ga
  • MGC-P-PUMP: Ex d ia IIC T4 Gb
  • ATEX: Sira 14ATEX2120
  • EN60079-0:2012, 60079-1:2014, 60079-11:2012, 60079-26:2007
  • MGC-IR-PUMP: CE ll 1 G Ex ia llC T4 Ga
  • MGC-P-PUMP: CE ll 1 G Ex d ia llC T4 Gb
  • InMetro: IEx 14.0326
  • ABNT NBR IEC 60079-0:2013, ABNT NBR IEC 60079-1:2009,
  • ABNT NBR IEC 60079-11:2013
  • MGC-IR-PUMP: Ex ia llC T4 Ga
  • MGC-P-PUMP: Ex d ia IIC T4 Gb
Gas Clip Technologies MGC-IR-PUMP Multi Gas Clip Pump IR 4 Gas Detector, Internal Pump & Infrared Combustible Sensor (H2S, CO, O2 & LEL)

PUMPED up multi gas detector with internal pump runs 52 hours continuously on a single charge


Features

  • 52 hour continuous run time - Operates with pump on for 52 hours continuously
  • Detects combustible gases (LEL), hydrogen sulfide (H2S), carbon monoxide (CO) & oxygen (O2)
  • 1 year calibration cycle saves valuable time & test gas
  • Will work in inert environments, no need for oxygen
  • Powerful but quiet pump draws from up to 75 feet
  • Stainless steel gas inlet
  • Detects accurately in oxygen-depleted environments
  • Low maintenance cost - infrared LEL sensor is immune to poisons
  • Simple to use, one button operation - large, easy to read screen
  • Lightweight & durable - alligator clip clamps on tight


Gas Clip MGC-IR-PUMP Specifications

Weight 352 g (12.4 oz)
Temperature -20 to 50°C (-0 to 122°F)
Humidity 5 to 100% RH non-condensing
Alarms Visual, Vibrating and Audible (minimum 95 db) Low, High, STEL, TWA and OL, Pump
TestsFull function self-test on activation and every 20 hours Continuous automatic battery and sensor tests
RatingsIP 67/ Complies with EMC directives 89/336/EEC
Battery Life 5 Days Continuous
GasesH2S: 0 to 100 PPM (0.1 PPM Increments)
CO: 0 to 500 PPM (1 PPM Increments)
Combustible Gas: 0 to 100% LEL (0.1% LEL Increments)
O2: 0 to 30% vol. (0.1% vol. Increments)


Calibrate the MGC Pump Once Every 12 Months
Other multi gas detectors require calibration anywhere from 1 to 3 months. The MGC Pump can go 12 months without being calibrated. This is an added benefit of IR sensing technology because IR is immune to pellistor sensor poisons such as silicone or H2S.


What's included with the Gas Clip MGC-IR-PUMP
  • Charger,
  • 10 foot sampling hose
  • Stainless steel diffusion stone
  • 10 additional filters (five hydrophobic and five particulate)
  • Calibration certificate
  • Quick Start Guide
.
Certifications & Approvals for MGC-IR-PUMP & MGC-P-PUMP

  • CSA: C22.2 No. 157 and C22.2 152 (MGC-IR-PUMP only)
  • Class I, Division 1, Group A, B, C, and D
  • MGC-IR-PUMP: Class I, Zone 0, AEx ia IIC T4 Ga
  • MGC-P-PUMP: Class I, Zone 1, AEx d ia IIC T4 Gb
  • UL-913 and ANSI/ISA-S12.13.01
  • IECEx: IECEx CSA 14.0029
  • IEC 60079-0:2011, 60079-1:2007, 60079-11:2011
  • MGC-IR-PUMP: Ex ia IIC T4 Ga
  • MGC-P-PUMP: Ex d ia IIC T4 Gb
  • ATEX: Sira 14ATEX2120
  • EN60079-0:2012, 60079-1:2014, 60079-11:2012, 60079-26:2007
  • MGC-IR-PUMP: CE ll 1 G Ex ia llC T4 Ga
  • MGC-P-PUMP: CE ll 1 G Ex d ia llC T4 Gb
  • InMetro: IEx 14.0326
  • ABNT NBR IEC 60079-0:2013, ABNT NBR IEC 60079-1:2009,
  • ABNT NBR IEC 60079-11:2013
  • MGC-IR-PUMP: Ex ia llC T4 Ga
  • MGC-P-PUMP: Ex d ia IIC T4 Gb
Gas Clip Technologies Multi Gas Clip Dock - Case, Regulator, Power Supply and USB Memory (MGC or MGC-P), MGC-Dock
Gas Clip Technologies Multi Gas Clip Dock - Case, Regulator, Power Supply and USB Memory (MGC or MGC-P), MGC-Dock

Recharge Cordless in the Field!
Test 4 units at a time, up to 12 per minute!